AliPhysics
114179e (114179e)
|
Switching to the EMCal correction framework is a straightforward process. It should be possible to configure with your desired settings in less than an hour.
If you plan to test and verify that everything works the same (which we strongly encourage!) be certain not to delete your previous corrections!
Follow the same procedure as described on EMCal Correction Framework.
To test and verify the changes, we have a general procedure, as well as tools to help verify automatically. NOTE: This procedure only works for analyses already using EMCal Containers! Older tasks must first update to at least use EMCal containers to use this tool! See here for instructions to update, if you need. Alternatively, you can test without EMCal containers, but these instructions do not apply.
The general procedure is as follows:
First, you must add some additional options to your run macro. In particular, we need to configure the EMCal Corrections Framework to copy cells, clusters, and tracks to ensure that the two sets of corrections do not interfere with each other. This has two simple steps:
To enable side-by-side testing, we will need to setup the copy of branches before setting up the EMCal Correction Framework AddTask. This is required to ensure that the two correction frameworks do not interfere with each other. To copy the proper input objects (we only need to copy cells and tracks - clusters will be created automatically), use something like the code below (assuming AOD branch naming):
The names in newBranchName
determine the name of the new branches. In principle, this could be anything, but we strongly recommend using the "usedefault" name and then adding "New" onto the end. So for AODs, it would be "emcalCellsNew" for cells, "caloClustersNew" for clusters, and "tracksNew" for tracks.
Before beginning, be certain to read the introduction to YAML and configuring corrections available here.
You can map the current corrections to the new ones with the following table. Note that each new correction is preceded by the name AliEmcalCorrection
:
Current Correction Name | New Correction Name |
---|---|
Tender | CellBadChannel |
CellEnergy | |
CellBadChannel | |
Clusterizer | Clusterizer |
ClusterMaker | ClusterExotics |
ClusterNonLinearity | |
ClusTrackMatcher | ClusterTrackMatcher |
HadCorr | ClusterHadronicCorrection |
Using the table above, we need to make sure that the current and the new corrections are configured the same. Compare the settings in your run macro with those in $ALICE_PHYSICS/PWG/EMCAL/config/AliEmcalCorrectionConfiguration.yaml
, known as the default file. In particular, check that each parameter value in the YAML file matches the value for that variable in your run macro (and not the other way around – it is okay if there is no matching field for every field in the AddTask). The variable names should often be the same. If values are different in the YAML file, then modify the values in **userTestConfiguration.yaml
**, not in AliEmcalCorrectionConfiguration.yaml
! To make the change, write it in yourself or copy the relevant structure of the default file to your user file and modify there. For instance, in the default file, the cellE
parameter in the Clusterizer is to 0.05
. If I wanted to change that in the user file, you would add:
Any setting that you have in the user file will override the default file!
In addition to determining the proper correction settings, the input objects need to be changed slightly. In parituclar, we need to change the branch names to the names defined when copying objects (described above)!
Configure your analysis task to run twice - once with the current corrections and once with the new corrections. To do so, configure your task once with different cluster and track (if needed) containers. Note that if you use jets, you need to run the jet finder twice - once for the old framework, and once for the new framework. For example, if you run on AODs, and set your cluster and track containers in run macro using "usedefault", then it would look something like:
Note**: If you don't use the "usedefault" pattern, then you'll have to set the names manually. You should just set the tracks and clusters names as usual.
As noted above, if you use jets, you will need to configure two jet finders. Due to using nonstandard track and cluster names to compare the two frameworks, the jet finder will not be configured properly if you just pass the names. Instead, you will need to remove the particle container and add a new track container based on the "tracksNew" branch. In code, it will look like,
If your analysis uses a track container, and you use the "usedefault" pattern in your analysis task AddTask, repeat the above lines (adapted for your task) for your task's track container.
You are all set! Now run the run macro as normal. Once it is finished, we have a python script to compare the output histograms automatically. It is available here (you may need to right click -> Save Link As..). To run it, you need to pass the path of the AnalysisResults.root
file, as well as the name of the output list from your task that was generated with the new corrections. For example,
If you don't know the name of your output list, just pass an invalid name to the -n
argument and it will show you the available options:
In exceptional cases, you will need to pass the name corresponding to the name of the output list from your task that was run with the current corrections. If needed, the script will inform you. For example,
If the outputs do not match initially, please double check your settings! If they still do not match, then consider running a statistical bin-by-bin comparsion. To do so, use the -s
option:
When running this statistical test, you can set the threshold for the fractional disagreement using the -t
option:
After all that, if they still do not match, then please let us know!
Help for the script is available with python compareHistos.py --help
. (If you are using aliBuild, you'll need to set your $PYTHONPATH
variable. In bash, you can do this by setting export PYTHONPATH=$ROOTSYS/lib:$PYTHONPATH
. Other shells may vary.)